Measuring Instruments · Process Analysis

Inline Process Refractometers

Hygienic inline refractometry for continuous measurement of refractive index, °Brix and concentration directly in production liquids. Explore L-Rix 5100 configurations, technical characteristics and Tetra Pak Part Number references for accurate component identification.

HomeProducts & ComponentsMeasuring InstrumentsAnalysisRefractometers
Technical Reference
0…100 °Brix measurement range shown for L-Rix 5100
0.1% Mass accuracy stated in the reference data
145°C CIP temperature reference for 30 minutes
13 Visible Tetra Pak Part Number entries
Continuous Process Measurement

Refractive index and concentration measurement directly in the process

The L-Rix 5100 is an optical hygienic inline refractometer intended for determination of refractive index (RI) in liquids. The instrument can be immersed directly in the production liquid and continuously displays °Brix and concentration values.

Inline refractometry provides continuous process information without the need to rely solely on intermittent laboratory sampling. The appropriate configuration depends on the required communication interface, display arrangement and Product Selection functionality.

Process Measurement

What the L-Rix 5100 measures

The instrument is designed for continuous optical measurement in liquid process streams, providing values relevant to concentration and product consistency.

01

Refractive Index

Optical measurement of refractive index (RI) directly in the production liquid.

02

°Brix

Continuous °Brix measurement for applications where dissolved-solids or concentration information is required.

03

Concentration

Continuous concentration values support real-time monitoring of process conditions and product changes.

L-Rix 5100 Benefits

Designed for hygienic inline measurement

The source information highlights hygienic design, robust materials, temperature compensation and straightforward operation.

High Accuracy

Accuracy stated as ± 0.1% mass, °Brix.

Hygienic Design

Designed for hygienic service and CIP/SIP-capable applications.

Stainless Steel Construction

Robust construction intended for continuous industrial operation.

Temperature Compensation

Automatic temperature compensation with integrated Pt100 Class A.

Sapphire Sensor

Sapphire sensor material provides high mechanical robustness.

Straightforward Operation

No special training is stated as necessary for setup and operation.

Product Selection

Product Selection Mode supports definition of up to 32 different products.

Continuous Measurement

Designed to remain directly integrated with the production liquid.

Technical Characteristics

L-Rix 5100 reference specifications

Key technical values below reproduce the specifications visible in the supplied Tetra Pak component reference.

L-Rix 5100

Varivent N inline refractometer with multiple communication and display configurations for hygienic process concentration measurement.

Process connection Varivent N
°Brix range 0…100 °Brix
Mass range 0…100 %mass
Accuracy 0.1
Cable gland M16x1.5
Power supply 24V DC
Protection IP67 / Nema4X
Measurement temperature Max 105°C
CIP 145°C (30 min)
Temperature sensor Integrated Pt100 Class A
Configuration Options

Communication and operating configurations

The Tetra Pak reference identifies L-Rix 5100 versions using three main output or communication arrangements.

NETWORK

Profinet

Available without display, with display, or with display and Product Selection.

NETWORK

Ethernet IP

Available without display, with display, or with display and Product Selection.

ANALOG

Analog Output

Reference configurations include versions with display and with display plus Product Selection.

OEM Reference Database

L-Rix 5100 Tetra Pak Part Numbers

The denomination, dimensions and Tetra Pak Part Number relationships below are preserved from the supplied source material.

13 Part Number Entries

L-Rix 5100

Instrument Configurations
Description Denomination A B Tetra Pak Part Number
L-Rix 5100 Profinet w/o display 142 160 90532-3756
L-Rix 5100 Profinet with display 142 160 90532-3757
L-Rix 5100 Profinet with display and product selection 142 160 90532-3758
L-Rix 5100 Ethernet IP w/o display 142 160 90532-3759
L-Rix 5100 Ethernet IP with display 142 160 90532-3760
L-Rix 5100 Ethernet IP with display and product selection 142 160 90532-3761
L-Rix 5100 Analog output with display 142 160 90532-3762
L-Rix 5100 Analog output with display and product selection 142 160 90532-3763

Varinline Deflectors

L-Rix 5100 Accessories
Description Denomination A B Tetra Pak Part Number
Deflectors Deflector, Varinline DN40 - - 90532-3766
Deflectors Deflector, Varinline DN50 - - 90532-3767
Deflectors Deflector, Varinline DN65 - - 90532-3768
Deflectors Deflector, Varinline DN80 - - 90532-3769
Deflectors Deflector, Varinline DN100 - - 90532-3770
Selection Guidance

Identifying the correct L-Rix 5100 configuration

Do not select the instrument from the L-Rix 5100 model name alone. The complete communication and operating configuration should be confirmed before ordering.

STEP 01

Identify the Interface

Confirm whether the installed instrument uses Profinet, Ethernet IP or analog output.

STEP 02

Check Display Configuration

Determine whether the required version is without display or equipped with a local display.

STEP 03

Confirm Product Selection

For relevant versions, confirm whether Product Selection functionality is required and verify the corresponding Tetra Pak Part Number.

Process Applications

Where inline refractometry adds process visibility

Continuous refractive-index and concentration measurement can support process monitoring wherever liquid concentration changes are important.

Food Processing

Continuous concentration and °Brix measurement directly in hygienic production liquids.

Beverage Processing

Inline monitoring of concentration values during production and product handling.

Dairy Processing

Process measurement in hygienic liquid applications where continuous concentration information is required.

Product Standardization

Continuous values can support monitoring of product concentration and consistency.

Process Change Detection

Refractive-index changes provide useful information when liquid composition changes during production.

Automated Process Control

Profinet, Ethernet IP and analog configurations provide options for integration with industrial control systems.

Frequently Asked Questions

L-Rix 5100 identification and sourcing

What does the L-Rix 5100 measure?

It is an optical inline refractometer for determination of refractive index in liquids and continuous display of °Brix and concentration values.

Are all L-Rix 5100 units interchangeable?

Not necessarily. Communication interface, display configuration and Product Selection functionality differ between the listed versions.

Which communication options are listed?

The supplied reference includes Profinet, Ethernet IP and analog-output configurations.

Are Varinline deflectors separately identified?

Yes. DN40, DN50, DN65, DN80 and DN100 deflectors each have their own Tetra Pak Part Number in the supplied reference.

How should I request a replacement?

Provide the existing Tetra Pak Part Number, complete denomination, instrument configuration and any available equipment identification.

Does LGN Group manufacture these Tetra Pak components?

No. The Tetra Pak Part Numbers shown here are OEM references used for technical identification and sourcing support.

Engineering Selection Support

Need help identifying an L-Rix 5100 refractometer?

Send LGN Group the Tetra Pak Part Number, denomination and available instrument information. Our team can assist with technical identification and sourcing of the required process component.

Request Technical Support