Measuring Instruments / Level

Capacitive Level Meters

Reliable capacitive level measurement solutions for hygienic tanks and process vessels, designed for continuous level monitoring in food, dairy, beverage and other sanitary process applications.

Home Measuring Instruments Level Capacitive Level Meter
Continuous Level Measurement

Capacitive Level Measurement for Process Tanks

Capacitive level instruments provide continuous monitoring of material level inside process tanks and vessels by detecting changes in electrical capacitance.

In hygienic processing plants, accurate and dependable level information supports process control, tank management, product handling and automation. The FMI51 configurations presented on this page are available with sanitary SMS and Tri-Clamp process connections.

FMI51 Configuration Highlights

  • Continuous capacitive level measurement
  • 316L stainless-steel housing
  • IP66 protection
  • 4–20 mA HART signal
  • M20 electrical connection
  • SMS and Tri-Clamp process connections
Measurement Principle

How Capacitive Level Measurement Works

The measurement principle detects variations in electrical capacitance caused by changes in the material surrounding the sensing probe.

01

Sensing Probe

The probe extends into the vessel and forms part of the capacitive measuring system.

02

Capacitance Change

As the process material level changes, the electrical capacitance detected by the instrument changes.

03

Continuous Signal

The measured value is converted into a continuous output signal for monitoring and process control.

Product Family

FMI51 Capacitive Level Meter Configurations

FMI51 level meters are available in different probe lengths and hygienic process connection configurations to suit different tank installations.

SMS CONNECTION

FMI51 SMS

FMI51 configuration with SMS process connection for hygienic tank and vessel level measurement.

Material 316L
Protection IP66
Output 4–20 mA HART
Electrical Connection M20
Available Lengths 1200 / 1620 / 2000 mm
TRI-CLAMP CONNECTION

FMI51 Tri-Clamp

FMI51 configuration with 2-inch Tri-Clamp hygienic process connection for sanitary tank installations.

Material 316L
Protection IP66
Output 4–20 mA HART
Electrical Connection M20
Process Connection Tri-Clamp 2 inch
Technical Benefits

Designed for Reliable Process Monitoring

Continuous Measurement

Continuous level information supports tank monitoring and automated process control.

Hygienic Connections

SMS and Tri-Clamp configurations support sanitary process installations.

Stainless-Steel Construction

316L stainless-steel housing is suitable for demanding hygienic process environments.

Process Integration

4–20 mA HART output supports integration with process monitoring and control systems.

Applications

Level Measurement in Hygienic Processing

Capacitive level meters can be integrated into tanks and process vessels where reliable continuous level information is required.

Dairy Processing

Level monitoring in hygienic tanks and vessels used throughout dairy process lines.

Beverage Production

Continuous monitoring of process and storage vessels within beverage production systems.

Food Processing

Tank level measurement for sanitary food production and process handling applications.

Process Tanks

Continuous level measurement for intermediate and production process vessels.

Storage Vessels

Reliable level information for hygienic storage and product holding tanks.

Automated Process Systems

Level feedback for integration into process monitoring and automation systems.

OEM Reference

FMI51 Configurations & Part Numbers

Reference configurations for FMI51 capacitive level meters with SMS and Tri-Clamp process connections.

Model Process Connection Probe Length Output Part Number
FMI51 SMS51 1200 mm 4–20 mA HART 90503-9838
FMI51 SMS51 1620 mm 4–20 mA HART 90503-9834
FMI51 SMS51 2000 mm 4–20 mA HART 90503-9837
FMI51 Tri-Clamp 2 inch 800 mm 4–20 mA HART 90503-9835
FMI51 Tri-Clamp 2 inch 840 mm 4–20 mA HART 90503-8694
FMI51 Tri-Clamp 2 inch 875 mm 4–20 mA HART 90503-8696
FMI51 Tri-Clamp 2 inch 1025 mm 4–20 mA HART 90503-9836
FMI51 Tri-Clamp 2 inch 1200 mm 4–20 mA HART 90503-8695

Part numbers are provided as equipment reference identifiers. Final instrument selection should be confirmed against the required process connection, probe length and application conditions.

Instrument Selection

Selecting the Correct Capacitive Level Meter

Correct configuration depends on the process vessel, connection standard, required probe length and process conditions.

Information to Confirm

  • Tank or vessel application
  • Required probe length
  • SMS or Tri-Clamp process connection
  • Process medium
  • Operating temperature
  • Operating pressure
  • Existing instrument or reference part number
Technical & Procurement Support

Looking for an FMI51 Level Meter?

Lian Giti Namdar supports industrial customers with instrument identification, technical selection and sourcing of level measurement equipment and related process components. Send us the required configuration, existing part number or equipment details for review.