The **LDL200** is an IO-Link plug&play, real-time temperature compensated conductivity sensor designed for conductivity measurement in the food industry. Its applications include product monitoring in dairies and the beverage industry, CIP (Cleaning-in-Place) system control, phase separation of product/water and product/product mixtures in pipe systems, and alkali and acid concentration control. When IO-Link is utilized, the LDL200 can perform both conductivity and temperature measurements.
Benefits
- Measuring range: 100 μS/cm to 1000 mS/cm.
- One 4-20 mA analog output with IO-link.
- PEEK sensor – wetted part and stainless steel integral housing.
- IP69K Protection – M12 Cable Connection.
- Measuring Accuracy: 2 % or MW ± 25 μS/cm.
- IO-link plug & play commissioning (no display or push button).
- Process temperature: -25...100 °C (can withstand up to 150 °C for less than 1 hour), suitable for CIP and SIP.
- Repeatability: 1 % MW ± 25 μS/cm.
- Integrated temperature measurement sensor.
CLD Transmitters for Inductive Sensors
Application
Transmitters for measurement of conductivity and concentration with inductive sensors for the food industry. Typical applications include product monitoring in dairies and the beverage industry, CIP system control, phase separation of product/water and product/product mixtures in pipe systems, and alkali and acid concentration control.
Benefits
- Transmitter housing made of stainless steel.
- Sensor made of highly resistant plastic (PEEK).
- Sterilizable sensor.
- High measuring reliability due to extensive self-monitoring functions.
- Insensitive to polarization and soiling.
- Sensor versions for all process connections used in hygienic applications.
- Large two-line display allows simultaneous display of measured value and temperature.
- Standard version extendable by function extension with remote measuring range switching.
CLD134 Specific Benefits
- EHEDG approval.
- Hygienic.
- Durable (protected sensor).
- Temperature compensation response time (t90 < 26 s).
CLD18 Specific Benefits
- EHEDG/3A approval.
- Durable.
- Temperature compensation response time (t90 < 50 s).
- Cost-effective.
- Compact.
CLS82D Conductivity Meter
Application
The CLS82D is a conductivity meter used for utilities and in effluent applications, including wastewater (for example, phase separation).
Benefits
- Used together with the Liquiline CM44x transmitter series.
- Broad measurement range.
- Hygienic design certified by EHEDG and 3-A.
- Absolute loop safety thanks to Memosens and unique electrode connection surveillance.
- Sterilizable and autoclavable.
Connectors and Adapters for SI6600/SI64700/SI6800
| Description | Denomination | Part No |
|---|---|---|
|
For LDL200 Please see Aseptoflex adapters on page: "Flow/Accessories" |
||
| (Information refers to external page) | ||
Inline Instrument Housings Varivent Varinline Compatible
| Description | Denomination | Part No |
|---|---|---|
|
Housing unit Go to "Integration components/Other Components/Inline housing". |
||
| (Information refers to external page) | ||
LDL200 IO-Link Models
| Description | Denomination | Part No |
|---|---|---|
|
LDL200 Connection: G1 Aseptoflex Electrical connection: 1xM12 plug 4-20mA + IO-Link |
||
| LDL200 G1A IO-Link | 70000139810 | |
CLD 134 Compact Models
| Description | Denomination | ABC | Multi range switch | Temp output | Part No |
|---|---|---|---|---|---|
|
DIN union Cable gland: M20x1.5 Connection: Dairy fitting DN50 DIN 11851 |
|||||
| CLD134 DN50 4-20mA 230V AC | 24478.592 | No | No | 90510-2608 | |
| CLD134 DN50 4-20mA 24V AC/DC | 24478.592 | No | No | 90529-5625 | |
|
SMS union Cable gland: M20x1.5 Connection: Dairy fitting SMS 51 |
|||||
| CLD134 SMS51 4-20mA 24V AC/DC | 24478.584 | No | No | 90511-0008 | |
|
Clamp Cable gland: M20x1.5 Connection: Clamp 51, ISO2852 |
|||||
| CLD134 ISO Cl51 2x(4-20mA) 24V AC/DC | 250.578.564.7 | No | Yes | 90600-1621 | |
| CLD134 ISO Cl51 4-20mA 24V AC/DC | 250.578.564.7 | No | Yes | 90522-1566 | |
| CLD134 ISO Cl51 4-20mA 24V AC/DC | 250.578.564.7 | No | Yes | 90512-1097 | |
CLD 134 Remote Models
| Description | Denomination | ABC | Multi range switch | Temp output | Part No |
|---|---|---|---|---|---|
|
DIN union Cable gland: M20x1.5 Connection: Dairy fitting DN50 DIN 11851 |
|||||
| CLD134 DIN50 2x(4-20mA) 24V AC/DC | 20714278.592 | No | No | 90519-8402 | |
| CLD134 DIN50 2x(4-20mA) 24V AC/DC | 20714278.592 | No | Yes | 90529-5626 | |
|
Clamp Cable gland: M20x1.5 Connection: Clamp 51, ISO 2852 |
|||||
| CLD134 Cl51 2x(4-20mA) 24V AC/DC | 20714278.5- | Yes | Yes | 90511-4904 | |
| CLD134 Cl51 4-20mA 24V AC/DC | 20714278.5- | Yes | No | 90511-4906 | |
| CLD134 ISO Cl51 2x(4-20mA) 24V AC/DC | 20714278.5- | No | Yes | 90503-8321 | |
| CLD134 ISO Cl51 2x(4-20mA) 24V AC/DC | 20714278.5- | Yes | Yes | 90526-5954 | |
|
Clamp USA Cable gland: NPT 1/2" Connection: Clamp 2" |
|||||
| CLD134 ISO Cl51 2x(4-20mA) 24V AC/DC | 20714278.5- | No | Yes | 90525-1654 | |
| CLD134 ISO Cl51 2x(4-20mA) 24V AC/DC | 20714278.5- | No | Yes | 90529-5651 | |
|
Varivent N Cable gland: M20x1.5 Connection: Varivent N |
|||||
| CLD134 VARIVENT 2x(4-20mA) 24V AC/DC | 20714236.5- | Yes | Yes | 90511-4905 | |
CLD18 Compact Models
| Description | Denomination | Part No |
|---|---|---|
|
DIN union Connection: Dairy fitting DN50 DIN 11851 SS housing IP69K NEMA6P |
||
| CLD18 DN50 DIN11851 SS Housing | 90522-8236 | |
|
Clamp Connection: Clamp 51, ISO 2852 SS housing IP69K NEMA6P |
||
| CLD18 Tri-Cl.2", SS house | 90520-0531 | |
|
SMS union Connection: Dairy fitting SMS51 SS housing IP69K NEMA6P |
||
| CLD18 SMS 2", SS house | 90520-0533 | |
|
Varivent N Connection: Varivent N SS housing IP69K NEMA6P |
||
| CLD18 Varivent N DN40-125, SS house | 90520-0532 | |
CLS82D Models
| Description | Denomination | Part No |
|---|---|---|
|
CLS82D 1 uS/cm-500 mS/cm Connection: G1" |
||
| Sensor, CLS82D PG 13.5 Pt1000 | 70000196668 | |