Conductivity Sensors & Tetra Pak Part Numbers | LGN Group
Measuring Instruments · Analysis

Conductivity Measurement Instruments

Conductivity sensors and transmitters for hygienic process monitoring, CIP control, phase separation and utility applications. This page consolidates technical reference data, model configurations and Tetra Pak Part Numbers for conductivity-related instruments.

HomeProducts & ComponentsMeasuring InstrumentsAnalysisConductivity
Reference Coverage
LDL200 IO-Link conductivity sensor
CLD134 Compact & remote transmitter variants
CLD18 Compact hygienic conductivity measurement
CLS82D Memosens conductivity sensor
Process Conductivity

Conductivity measurement for hygienic process control

Conductivity is widely used in food and beverage processing to monitor CIP concentration, distinguish product from water, verify phase separation and supervise utility or effluent streams. Correct instrument selection depends on process connection, output type, temperature requirements and the exact transmitter or sensor configuration.

The tables below preserve the visible relationships between denomination, connection type, optional features and Tetra Pak Part Numbers from the supplied reference screenshots.

Instrument Families

Main conductivity product groups

The source page combines compact and remote transmitters, IO-Link sensors, Memosens sensors and hygienic connection variants.

01

LDL200 IO-Link

Real-time temperature compensated conductivity sensing with 4–20 mA and IO-Link.

02

CLD134 Compact

Compact hygienic transmitter variants with multiple connection and output combinations.

03

CLD134 Remote

Remote transmitter configurations with DIN, Clamp USA and Varivent N connections.

04

CLD18 Compact

Compact hygienic conductivity transmitters for DIN, Clamp, SMS and Varivent connections.

05

CLS82D

Memosens conductivity sensor for utility and effluent applications.

06

Connections & Housings

Reference sections for adapters and Varivent Varinline compatible inline housings.

Technical Overview

Applications and technical benefits

IO-Link Sensor

LDL200

IO-Link 4–20 mA G1

The LDL200 is described as an IO-Link plug-and-play, real-time temperature compensated conductivity sensor for the food industry. It is used for product monitoring, CIP control, phase separation, alkali and acid concentration control and, with IO-Link, conductivity plus temperature measurement.

  • Measuring range 100 µS/cm to 1000 mS/cm
  • One 4–20 mA analogue output with IO-Link
  • PEEK sensor, wetted part, with stainless steel integral housing
  • IP69K protection with M12 cable connection
  • Measuring accuracy 2 % or MW ± 25 µS/cm
  • IO-Link plug & play commissioning
  • Process temperature -25...100 C; (< 1 h: 150) suitable for CIP and SIP
  • Repeatability 1 % MW ± 25 µS/cm
  • Integrated temperature measurement sensor
CLD Transmitters

CLD Series

CLD134 CLD18

The CLD transmitters are described for conductivity and concentration measurement using inductive sensors in food-industry applications, including product monitoring, CIP control, phase separation and alkali/acid concentration control.

  • Stainless steel transmitter housing
  • Sensor made of highly resistant plastic (PEEK)
  • Sterilisable sensor
  • Extensive self-monitoring functions
  • Insensitive to polarisation and soiling
  • Sensor versions for process connections used in hygienic applications
  • Large two-line display for measured value and temperature
  • Standard version extendable by function extension with remote measuring range switching
Compact / Remote

CLD134

EHEDG approval Hygienic
  • EHEDG approval
  • Hygienic design
  • Durable protected sensor
  • Temperature compensation response time t90 < 26 s
Compact

CLD18

EHEDG / 3A Compact
  • EHEDG/3A approval
  • Durable
  • Temperature compensation response time t90 < 50 s
  • Cost effective
  • Compact
Memosens Sensor

CLS82D

Memosens G1

The CLS82D is a conductivity meter used for utilities and effluent applications including wastewater, for example phase separation.

  • Used together with the Liquiline CM44x transmitter series
  • Broad measurement range
  • Hygienic design certified by EHEDG and 3-A
  • Absolute loop safety through Memosens and electrode connection surveillance
  • Sterilizable and autoclavable
Selection Guidance

How to identify the correct conductivity configuration

Because several models share similar names, the connection, power/output configuration and optional columns must be checked together with the Part Number.

Step 01

Confirm the family

Identify LDL200, CLD134 Compact, CLD134 Remote, CLD18 Compact or CLS82D.

Step 02

Match the connection

Check DIN, SMS, Clamp, Clamp USA or Varivent N, including connection-specific dimensions where shown.

Step 03

Verify output options

For CLD134, preserve Multi range switch and Temp output values because they distinguish otherwise similar variants.

OEM Reference Database

Tetra Pak Part Number reference

The following tables reproduce the visible model-to-configuration relationships from the supplied screenshots. Blank connector/housing rows are not assigned invented Part Numbers.

LDL200 IO-Link

Conductivity Sensor
Description Denomination Tetra Pak Part No
LDL200
Connection: G1
Aseptoflex
Electrical connection: 1xM12 plug
4-20mA + IO-Link
LDL200 G1A IO-Link 70000139810

CLD134 Compact

Compact Transmitter
Description Denomination A B C Multi range switch Temp output Tetra Pak Part No
DIN union
Cable gland: M20x1.5
Connection: Dairy fitting DN50 DIN 11851
CLD134 DN50 4-20mA 230V AC 244 78.5 92 No No 90510-2608
CLD134 DN50 4-20mA 24V AC/DC 244 78.5 92 No No 90529-5625
SMS union
Cable gland: M20x1.5
Connection: Dairy fitting SMS 51
CLD134 SMS51 4-20mA 24V AC/DC 244 78.5 84 No No 90511-0008
Clamp
Cable gland: M20x1.5
Connection: Clamp 51, ISO2852
CLD134 ISO CI51 2x(4-20mA) 24V AC/DC 250.5 78.5 64.7 No Yes 90600-1621
CLD134 ISO CI51 4-20mA 24V AC/DC 250.5 78.5 64.7 No Yes 90522-1566
CLD134 ISO CI51 4-20mA 24V AC/DC 250.5 78.5 64.7 No Yes 90512-1097

CLD134 Remote

Remote Transmitter
Description Denomination A B C D Multi range switch Temp output Tetra Pak Part No
DIN union
Cable gland: M20x1.5
Connection: Dairy fitting DN50 DIN 11851
CLD134 DIN50 2x(4-20mA) 24V AC/DC 207 142 78.5 92 No No 90519-8402
CLD134 DIN50 2x(4-20mA) 24V AC/DC 207 142 78.5 92 No Yes 90529-5626
Clamp
Cable gland: M20x1.5
Connection: Clamp 51, ISO 2852
CLD134 CI51 2x(4-20mA) 24V AC/DC 207 142 78.5 - Yes Yes 90511-4904
CLD134 CI51 4-20mA 24V AC/DC 207 142 78.5 - Yes No 90511-4906
CLD134 ISO CI51 2x(4-20mA) 24V AC/DC 207 142 78.5 - No Yes 90503-8321
CLD134 ISO CI51 2x(4-20mA) 24V AC/DC 207 142 78.5 - Yes Yes 90526-5954
Clamp USA
Cable gland: NPT 1/2"
Connection: Clamp 2"
CLD134 ISO CI51 2x(4-20mA) 24V AC/DC 207 142 78.5 - No Yes 90525-1654
CLD134 ISO CI51 2x(4-20mA) 24V AC/DC 207 142 78.5 - No Yes 90529-5651
Varivent N
Cable gland: M20x1.5
Connection: Varivent N
CLD134 VARIVENT 2x(4-20mA) 24V AC/DC 207 142 36.5 - Yes Yes 90511-4905

CLD18 Compact

Compact Conductivity Transmitter
Description Denomination Tetra Pak Part No
DIN union
Connection: Dairy fitting DN50 DIN 11851
SS housing
IP69K
NEMA6P
CLD18 DN50 DIN11851 SS Housing 90522-8236
Clamp
Connection: Clamp 51, ISO 2852
SS housing
IP69K
NEMA6P
CLD18 Tri-Cl.2 inch, SS house 90520-0531
SMS union
Connection: Dairy fitting SMS51
SS housing
IP69K
NEMA6P
CLD18 SMS 2 inch, SS house 90520-0533
Varivent N
Connection: Varivent N
SS housing
IP69K
NEMA6P
CLD18 Varivent N DN40-125, SS house 90520-0532

CLS82D

Conductivity Sensor
Description Denomination Tetra Pak Part No
CLS82D
1 uS/cm–500 mS/cm
Connection: G1"
Sensor, CLS82D PG 13.5 Pt1000 70000196668

Connectors and adapters for SI6600/SI64700/SI6800

No visible Part No in supplied screenshot
Description Denomination Tetra Pak Part No
For LDL200
Please see Aseptoflex adapters on page: "Flow/Accessories"

Inline instrument housings Varivent Varinline compatible

No visible Part No in supplied screenshot
Description Denomination Tetra Pak Part No
Housing unit
Go to "Integration components/Other Components/Inline housing".
Applications

Typical conductivity measurement applications

Conductivity measurement is especially useful where fast process-state changes need to be identified without direct product sampling.

01

CIP concentration control

Monitoring alkali and acid concentration during cleaning cycles and helping distinguish rinse water from cleaning media.

02

Product / water separation

Detecting phase transitions in pipelines to reduce product loss and support controlled routing.

03

Utilities & effluent

Conductivity measurement in process water, wastewater and utility streams.

04

Dairy processing

Process monitoring in hygienic dairy applications where connection design and cleanability are important.

05

Beverage processing

Inline conductivity monitoring for phase separation, product routing and CIP supervision.

06

Automation integration

4–20 mA, IO-Link and transmitter options support integration with process control systems.

FAQ

Conductivity instrument identification and sourcing

Why can identical CLD134 denominations have different Part Numbers?

The screenshots show variants distinguished by configuration fields such as multi-range switch, temperature output, connection type and power/output arrangement. The Part Number should always be checked together with those fields.

Can LGN Group identify a replacement from a Tetra Pak Part Number?

Yes. A visible Tetra Pak Part Number, complete denomination and installed model are the most useful starting references for technical identification and sourcing support.

Are blank adapter and housing rows assigned Part Numbers here?

No. Where the supplied screenshot did not display a Part Number, this page leaves the field blank rather than inventing an OEM reference.

What information should be sent with an inquiry?

Send model, Part Number, denomination, process connection, output or power configuration and a nameplate/photo when available.

Engineering Selection Support

Need help identifying a conductivity sensor or transmitter?

Send the Tetra Pak Part Number, model, denomination and available process details. LGN Group can support technical identification and sourcing of the correct replacement configuration.

Request Technical Support