Measuring Instruments · Process Analysis

Other Process Analysis Instruments

Process analysis transmitters and sensors for pH, optical absorption, turbidity, nitrate and related measurement duties in food, dairy, beverage, water and utility systems. LGN supports technical identification, OEM reference matching and replacement component sourcing.

HomeProducts & ComponentsMeasuring InstrumentsAnalysisOther
Reference coverage
23 Tetra Pak Part Number entries captured from the supplied reference
8+ analysis instrument and accessory families represented
pH sensor and Memosens measurement references
NTU turbidity and optical process monitoring solutions
Process Measurement

Specialized instruments for process and utility analysis

Modern food and beverage plants require more than pressure, temperature and flow measurement. Analytical parameters such as pH, turbidity, optical absorption and nitrate concentration can provide important information about product transitions, water quality, cleaning processes and utility performance.

This page brings together additional analytical instruments and related components referenced for Tetra Pak processing installations. The technical reference tables retain the denomination and Part Number relationships shown in the supplied Tetra Pak component information.

Instrument Families

Analysis components represented in this reference

The supplied component material covers transmitters, analytical sensors, turbidity instruments and associated measuring accessories.

01

Analysis Transmitters

Liquiline CM44x family references including CM44P and CM442R configurations.

02

pH Measurement

Digital pH sensor references for water and process measurement applications.

03

Optical Absorption

Inline optical sensing for phase detection and suspended-solids-related duties.

04

Turbidity

Turbimax sensors and ITM-51 inline turbidity instrument configurations.

05

Nitrate Measurement

Viomax CAS51D reference for nitrate or SAC measurement applications.

06

Chlorine Measurement

Digital free-chlorine measurement represented by CCS142D in the supplied technical reference.

07

Sensor Assemblies

Process installation accessory reference including CPA842 assembly.

08

Measuring Cables

Memosens CYK10 cable references for analytical sensor connections.

Technical Overview

Key analytical measurement families

The following summary is based on the applications and benefits visible in the supplied technical reference.

Transmitter

Liquiline CM44x Series

CM44P CM442R Memosens

The Liquiline CM44x series is represented as a transmitter platform for Memosens technology. The supplied reference includes both rack-mounted and field-oriented configurations.

  • Controller platform for multiple analytical parameters and applications.
  • Automatic sensor recognition with pre-calibrated Memosens sensors.
  • Modular configuration intended to support flexible measurement arrangements.
  • Configuration and diagnostic capabilities for process control applications.
pH

Digital pH Sensors

CPS11E CPS11D reference Memosens

The supplied material represents pH sensors for water-treatment, drinking-water, cooling-water and related process measurement duties.

  • Non-contact inductive signal transmission is referenced for process safety.
  • Sensor and process-specific data can support predictive maintenance.
  • Designed for stable analytical measurement in water-related applications.
Optical Absorption

OUSAF11

OUSAF11 CM44P Varivent N

OUSAF11 is represented as a glass-free sensor for inline detection of changing phases and suspended solids.

  • Glass-free hygienic sensor design.
  • Fast interphase detection can reduce product losses.
  • Designed for low-maintenance operation and chemical resistance.
  • Suitable for CIP and SIP duties according to the supplied reference.
  • FDA and 3-A approval are stated in the reference material.
Turbidity

Turbimax & ITM-51

CUS51D CUS52D ITM-51

The turbidity group covers both Memosens sensor solutions and hygienic inline ITM-51 configurations used for phase-separation and turbidity measurement.

  • CUS51D is referenced for suspended solids and turbidity measurement in water, wastewater and utilities.
  • CUS52D is represented for hygienic turbidity measurement in drinking water, process water and utilities.
  • ITM-51 is shown for phase separation applications such as water/milk transitions and products such as cream and whey.
Nitrate

Viomax CAS51D

CAS51D Nitrate SAC

Viomax CAS51D is represented for nitrate or SAC measurement in drinking water, process water, wastewater and utility applications.

  • Chemical-free measurement approach is referenced for reduced operational expenditure.
  • Sensor-based measured-value processing supports fast response.
  • Factory pre-calibration and pre-configuration are referenced.
  • Suitable for flexible installation arrangements with relevant holders and assembly systems.
Chlorine

CCS142D

CCS142D Free Chlorine

CCS142D is represented in the supplied reference as a digital free-chlorine sensor for water applications.

  • Long calibration and maintenance intervals.
  • Prefabricated membrane-cap arrangement for easier membrane replacement.
  • Measured values are stated as unaffected by conductivity fluctuation.
  • Flow-cell and immersion installation arrangements are referenced.
Identification Guidance

How to identify the correct replacement component

The model name alone may not be sufficient. Always compare the complete configuration and reference information before sourcing a replacement.

Step 01

Identify the model

Check the instrument designation such as CM44P, CUS52D, ITM-51, CAS51D or CYK10.

Step 02

Match the denomination

Connection, display arrangement, cable length and electronics can distinguish one configuration from another.

Step 03

Confirm the Part Number

Use the exact Tetra Pak Part Number where available rather than relying only on visual similarity.

OEM Reference Database

Complete Tetra Pak Part Number references

The following denomination-to-Part-Number relationships are preserved from the supplied Tetra Pak Components reference. Part Numbers are shown exactly as visible in the source screenshots.

23 Part Number entries

Analysis Transmitters

CM44x Series
Model / Description Denomination Tetra Pak Part Number
CM44P CM44P multi.2x0/4-20mA 2DI 2DO 90524-6671
CM442R CM442R multi.2x0/4-20mA 2DI 2DO 90524-6673
CM442R CM442R multi.W/O I/O 90524-6674

pH

pH Electrode
Model / Description Denomination Tetra Pak Part Number
CPS11E PH-electrode, CPS11E 1-12pH 120mm 90533-0641

Optical Absorption

OUSAF11
Description Denomination Tetra Pak Part Number
OUSAF11
Sensor for CM44P transmitter
3 m cable
Connection: Varivent N
"0-2,5 AU;(up to 0-5 OD) OPL 5mm" 90524-6666

Turbidity

Turbimax & ITM-51
Model / Description Denomination Tetra Pak Part Number
Turbimax CUS51D
3 m cable
Turbimax CUS51D G1 NPT3/4 90524-6669
Turbimax CUS52D
3 m cable
Turbimax CUS52D G1 NPT3/4 90524-6670
ITM-51 Analog, Compact

18-36V DC
4-20mA, 4-wire
-1-20bar
temp.-10-130deg.C/CIP 140deg.C
M12 plug
1.4301, vertical
Infrared backscatter method
color independent
Optical: Sapphire
ITM-51 Tri-Cl.1-1/2 inch w. display 70000163302
ITM-51 Tri-Cl.1-1/2 inch w. long sensor w. display 90532-7924
ITM-51 Tri-Cl.2 inch w. display 70000164890
ITM-51 Varivent N w. display 90532-7926
ITM-51 Analog, Remote

18-36V DC
4-20mA, 4-wire
-1-20bar
temp.-10-130deg.C/CIP 140deg.C
M12 plug
1.4301, vertical
Infrared backscatter method
color independent
Optical: Sapphire
ITM-51 Tri-Cl.1-1/2 inch w. display 90532-7922
ITM-51 Tri-Cl.2 inch w. display 90532-7923
Cable for remote version
5 meter cable for remote version of ITM-51
5-meter cable 90526-8294
ITM-51 IO-Link, Compact

18-36V DC
IO-Link + 4-20mA, 5-wire
-1-20bar
temp.-10-130deg.C/CIP 140deg.C
Display, M12 plug
1.4301, vertical
Infrared backscatter method
color independent
Optical: Sapphire
ITM-51 Tri-Cl.1-1/2 inch w display 70000164615
ITM-51 Tri-Cl.1-1/2 inch w. long sensor w/o display 90532-7925
ITM-51 Tri-Cl.1-1/2 inch w/o display 90532-7920
ITM-51 Tri-Cl.2 inch w/o display 90532-7921
ITM-51 Varivent N w/o display 90532-7927
ITM-51 technical wording and denominations above are retained from the supplied component reference. Confirm the complete installed configuration before replacement.

Nitrate

Viomax CAS51D
Description Denomination Tetra Pak Part Number
Viomax CAS51D
UV-range
Nitrate clear water
0,01-20mg/l NO3-N or
0,04-80mg/l NO3
Viomax CAS51D sensor 90524-6676

Analysis Accessories

Assembly & Measuring Cable
Model / Description Denomination Tetra Pak Part Number
CPA842
Assembly
Assembly, Unifit CPA842 90530-6331
CYK10 Measuring cable CYK10 Memosens, pH 10m 90524-6679
CYK10 Measuring cable CYK10 Memosens, pH 5m 90524-6678
Configuration Reference

ITM-51 configurations

The supplied Tetra Pak component table separates the ITM-51 family into analog compact, analog remote and IO-Link compact arrangements.

ITM-51 Analog, Compact

Supply 18-36V DC
Output 4-20mA, 4-wire
Pressure -1-20bar
Temperature -10-130deg.C
CIP 140deg.C
Optical Sapphire

ITM-51 Analog, Remote

Supply 18-36V DC
Output 4-20mA, 4-wire
Pressure -1-20bar
Temperature -10-130deg.C
CIP 140deg.C
Remote cable 5 meter reference available

ITM-51 IO-Link, Compact

Supply 18-36V DC
Interface IO-Link + 4-20mA
Wiring 5-wire
Pressure -1-20bar
Temperature -10-130deg.C
CIP 140deg.C
Applications

Typical process analysis duties

Selection depends on the required analytical parameter, process medium, hygienic requirements, installation arrangement and control-system interface.

01

Food & Dairy Processing

Inline phase detection, product transition monitoring and analytical measurement in hygienic production systems.

02

Process Water

Turbidity, pH, nitrate and related analytical measurements in process and production-water systems.

03

Utilities

Monitoring of water and utility systems where analytical measurement supports process stability and quality control.

04

Water Treatment

Analytical sensor applications for drinking water, cooling water, wastewater and associated treatment duties.

05

Phase Separation

Turbidity and optical measurement can help detect transitions between water, milk and other process media.

06

Automation Integration

Transmitter, analog and IO-Link configurations provide different options for integration into process-control architectures.

FAQ

Process analysis component identification

Can LGN identify a component from a Tetra Pak Part Number?

Yes. Providing the existing Tetra Pak Part Number together with instrument model and application information is one of the most reliable starting points for component identification.

Is the model name alone enough?

Not always. Some models are available with different process connections, cable lengths, electronics, display arrangements or installation versions.

Are all listed components manufactured by LGN?

No. The Part Numbers on this page are OEM references used for technical identification and sourcing support. LGN does not present these references as LGN-manufactured OEM products.

What information should be provided with an inquiry?

Send the Part Number, model, full denomination, equipment information, photographs of the installed item and any available connection or process details.

Why are some instrument families shown without a Part Number?

A Part Number is only published here when it is visible in the supplied reference material. LGN does not generate or infer missing OEM numbers.

Can LGN assist with obsolete or difficult-to-identify components?

LGN can review available identification data and support sourcing or replacement-component evaluation based on the information provided.

Engineering Selection Support

Need help identifying an analysis instrument?

Send LGN the existing Tetra Pak Part Number, instrument model, denomination and available equipment information. Our team can assist with technical identification and replacement component sourcing.

Request Technical Support