Measuring Instruments · Flow

Vortex Flowmeters

Vortex flow measurement for steam, condensate, gases and liquids. Explore Prowirl F200 C Generation, Prowirl D200 C Generation and Prowirl F200 configurations together with Tetra Pak Part Numbers for technical identification and sourcing support.

Home › Products & Components › Measuring Instruments › Flow › Vortex Flowmeters
Process flow measurement

Prowirl vortex flowmeter families

The supplied component reference covers Prowirl vortex instruments for saturated steam mass measurement, volumetric measurement in condensate water and non-conductive liquids, and broader wet/saturated/superheated steam, gas and liquid applications.

Exact replacement identification requires the complete model code, nominal size, process connection and Tetra Pak Part Number rather than the family name alone.

Prowirl F200 C Saturated steam
Prowirl D200 C Volumetric liquids
Prowirl F200 Steam, gas & liquids
OEM References Exact PN matching
Product families

Configurations in the supplied OEM reference

Prowirl F200 C Generation

Steam mass measurement

Specified for saturated steam mass measurement, with integrated temperature measurement for mass/energy flow and Heartbeat functionality referenced in the source.

Prowirl D200 C Generation

Condensate & non-conductive liquids

Wafer-style family referenced for volumetric measurement in condensate water and non-conductive liquids.

Prowirl F200

Broad vortex applications

Referenced as a preferred measuring principle for wet, saturated and superheated steam, gases and liquids, including cryogenic applications.

Technical benefits

Measurement and process advantages

Integrated temperature The supplied reference highlights integrated temperature measurement for saturated-steam mass and energy flow.
Heartbeat functionality Prowirl F200 C Generation references real-time sensor self-diagnostic check and verification.
Wet steam capability The source states wet-steam capabilities for DN25 to DN300 for the F200 C Generation family.
Long-term stability Robust, drift-free operation is highlighted for the Prowirl families in the supplied reference.
Wafer process connection Prowirl D200 C Generation is presented as a cost-effective wafer solution with low weight and no flanges.
Process resilience The D200 reference highlights resistance to vibration, temperature shocks and water hammer.
OEM reference database

Tetra Pak Part Numbers

The tables preserve the visible denomination-to-Part-Number relationships from the supplied Tetra Pak Components screenshots.

Prowirl F200 C Generation — ANSI B 16.5 Flange ANSI B 16.5 · 4-20mA HART · integrated temperature sensor · NPT 1/2"
Denomination Size Tetra Pak Part No.
Prowirl F200, 7F2C25, 1 inch 1 inch 90531-2228
Prowirl F200, 7F2C40, 1 1/2 inch 1 1/2 inch 90531-2229
Prowirl F200, 7F2C50, 2 inch 2 inch 90531-2230
Prowirl F200, 7F2C80, 3 inch 3 inch 90531-2231
Prowirl F200, 7F2C1H, 4 inch 4 inch 90531-2232
Prowirl F200, 7F2C1F, 6 inch 6 inch 90531-2233
Prowirl F200 C Generation — EN1092-1-B1 PN40 flange EN1092-1-B1 · 4-20mA HART · Touch Button Display · integrated temperature sensor · Gland M20
Denomination DN Tetra Pak Part No.
Prowirl F200, 7F2C25, DN25 DN25 90531-2234
Prowirl F200, 7F2C40, DN40 DN40 90531-2235
Prowirl F200, 7F2C50, DN50 DN50 90531-2236
Prowirl F200, 7F2C80, DN80 DN80 90531-2237
Prowirl F200, 7F2C1H, DN100 DN100 90531-2238
Prowirl F200, 7F2C1F, DN150 DN150 90531-2239
Prowirl D200 C Generation EN1092-1-B1 · 4-20mA HART · without display · without temperature sensor · compact sensor · aluminium housing · Gland M20
Denomination DN Tetra Pak Part No.
Prowirl D200, 7D2C25, DN25 DN25 90531-2240
Prowirl D200, 7D2C40, DN40 DN40 90531-2241
Prowirl D200, 7D2C50, DN50 DN50 90531-2242
Prowirl D200, 7D2C80, DN80 DN80 90531-2243
Prowirl D200 C Generation — Mounting Sets Nuts, bolts and gaskets for Prowirl D200 C Generation
Denomination DN Tetra Pak Part No.
Prowirl D, mounting set DN25 DN25 90531-2244
Prowirl D, mounting set DN40 DN40 90531-2245
Prowirl D, mounting set DN50 DN50 90531-2246
Prowirl D, mounting set DN80 DN80 90531-2247
Prowirl F200 Visible Prowirl entries in the supplied reference
Denomination DN Tetra Pak Part No.
Prowirl F200 DN50 Fl.EN1092-1-B1 DN50 90531-0107
Prowirl F200 DN80 Fl.EN1092-1-B1 DN80 90531-0108
Prowirl F200 DN100 Fl.EN1092-1-B1 DN100 90531-2580
OEM identification note: model codes, connection standards, sizes and Tetra Pak Part Numbers are intentionally preserved in their technical form. No Part Number has been created or inferred beyond the visible supplied reference.
Selection guidance

How to identify the correct Prowirl configuration

STEP 01

Confirm the family

Identify Prowirl F200 C Generation, Prowirl D200 C Generation or Prowirl F200.

STEP 02

Confirm application

Determine whether the duty is steam mass/energy flow, condensate, gas or liquid flow measurement.

STEP 03

Match connection & size

Check ANSI or EN flange/wafer configuration and the exact inch or DN size.

STEP 04

Match the OEM code

Verify the complete denomination and Tetra Pak Part Number before ordering or replacement.

Applications

Typical process duties represented by the range

Steam systems

Saturated, wet and superheated steam measurement, including steam mass and energy-flow duties.

Condensate systems

Volumetric measurement of condensate water and other suitable liquid duties.

Gas & liquid utilities

Prowirl F200 is represented for a broad range of gas and liquid flow applications.

FAQ

Vortex flowmeter identification

What is the main application of Prowirl F200 C Generation?

The supplied reference identifies saturated steam mass measurement and highlights integrated temperature measurement for mass/energy flow.

What is Prowirl D200 C Generation used for?

The supplied reference identifies volumetric measurement in condensate water and non-conductive liquids and describes wafer process connections.

Can the same Tetra Pak Part Number be used for different sizes?

No. The visible reference assigns different Part Numbers to different model codes, nominal sizes and configurations.

Are the Tetra Pak Part Numbers manufacturer model numbers?

No. The tables distinguish the Prowirl denomination/model configuration from the corresponding Tetra Pak Part Number used as an OEM reference.

Does LGN Group manufacture these components?

No. Tetra Pak Part Numbers are presented as OEM references for technical identification and sourcing support.

Engineering selection support

Need help identifying a Prowirl vortex flowmeter?

Send LGN Group the existing Tetra Pak Part Number, Prowirl model/code, process connection, nominal size, application and available nameplate information for technical identification and sourcing support.

Request Technical Support