Coriolis Flowmeters
Hygienic Coriolis flowmeters for direct mass flow, density and concentration measurement in dairy, beverage and process applications. Explore Promass E, F and Q series configurations together with Tetra Pak Part Numbers for accurate technical identification and sourcing support.
Coriolis measurement for hygienic process lines
The supplied reference presents Promass Coriolis instruments for simultaneous direct mass-flow and density measurement in dairy and beverage applications. Examples shown include milk, cream, chocolate, oil, fruit juice, puree, low-conductivity liquids and gas applications such as CO2 in CSD processes.
Additional use cases include Brix and concentration measurement, premium density measurement, entrained-gas applications and fluid temperatures up to +200°C for the Promass F 100 family.
Promass families in the supplied OEM reference
The screenshots cover five primary model families and multiple clamp, union, flange, PROFINET IO, Ethernet IP and analog configurations.
Promass E 100
Compact hygienic Coriolis configurations with clamp, DIN and SMS connections and multiple communication options.
Promass E 300
Display-equipped family shown with clamp, DIN union, DIN flange and SMS union connections.
Promass F 100
Compact high-performance family shown with Tri-clamp and digital communication options.
Promass F 300
High-accuracy direct mass and density measurement with display and Tri-clamp configuration.
Promass Q 300
Premium density family shown with Tri-clamp and SMS union versions, with and without display.
Measurement capabilities highlighted in the source
Promass families are presented for simultaneous direct mass-flow and density measurement.
The source explicitly references Brix and concentration measurement in process applications.
Polished measuring tubes, stainless-steel housings and hygienic approvals are visible across multiple configurations.
Promass F 100 is explicitly described as suitable for CIP/SIP cleaning.
Promass Q 300 highlights ultra-high density accuracy of ±0.0002 g/cm³ and flow accuracy of ±0.1%.
Promass Q 300 is described for entrained-gas applications with real-time error compensation for air-bubble content.
Tetra Pak Part Numbers
The following tables preserve the visible denomination-to-Part-Number relationships from the supplied screenshots.
Promass E 100
Compact hygienic configurations
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| Clamp connection / Profinet · Profinet IO · +/- 0.15 accuracy for mass flow · polished tubes 0.76um · 3A certified | Flowmeter E100 1 inch 0-18.000 kg/h | 90532-0167 |
| Same configuration | Flowmeter E100 1-1/2 inch 0-45.000 kg/h | 90532-0168 |
| Same configuration | Flowmeter E100 2 inch 0-65.000 kg/h | 90532-0169 |
| Same configuration | Flowmeter E100 3 inch 0-180.000 kg/h | 90532-0170 |
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| Clamp connection / Profinet · EHEDG certified | Flowmeter E100 1 inch 0-18.000 kg/h | 90532-0171 |
| Same configuration | Flowmeter E100 1-1/2 inch 0-45.000 kg/h | 90532-0172 |
| Same configuration | Flowmeter E100 2 inch 0-65.000 kg/h | 90532-0173 |
| Same configuration | Flowmeter E100 3 inch 0-180.000 kg/h | 90532-0174 |
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| Clamp connection / Ethernet · Ethernet IP · polished tubes 0.76um · 2xM12 · 3A certified | Flowmeter E100 1 inch 0-18.000 kg/h | 90532-0175 |
| Same configuration | Flowmeter E100 1-1/2 inch 0-45.000 kg/h | 90532-0176 |
| Same configuration | Flowmeter E100 2 inch 0-65.000 kg/h | 90532-0177 |
| Same configuration | Flowmeter E100 3 inch 0-180.000 kg/h | 90532-0178 |
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| Clamp connection / Analog · Analog 4_20mA · polished tubes 0.76um · 2xM12 | Flowmeter E100 1 inch 0-18.000 kg/h | 90532-0191 |
| Same configuration | Flowmeter E100 1-1/2 inch 0-45.000 kg/h | 90532-0192 |
| Same configuration | Flowmeter E100 2 inch 0-65.000 kg/h | 90526-7602 |
| Same configuration | Flowmeter E100 3 inch 0-180.000 kg/h | 90532-0193 |
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| DIN 11864-1A union / Profinet · SS housing without display · 2xM12 | Flowmeter E100 DN25 0-18.000 kg/h | 90532-0159 |
| Same configuration | Flowmeter E100 DN40 0-45.000 kg/h | 90532-0160 |
| Same configuration | Flowmeter E100 DN50 0-65.000 kg/h | 90532-0161 |
| Same configuration | Flowmeter E100 DN80 0-180.000 kg/h | 90532-0162 |
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| SMS union / Profinet · 2xM12 · polished tubes 0.76um | Flowmeter E100 SMS25 0-18.000 kg/h | 90532-0163 |
| Same configuration | Flowmeter E100 SMS38 0-45.000 kg/h | 90532-0164 |
| Same configuration | Flowmeter E100 SMS51 0-65.000 kg/h | 90532-0165 |
| Same configuration | Flowmeter E100 SMS76.1 0-180.000 kg/h | 90532-0166 |
Promass E 300
Analog version with display
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| Clamp connection · Analog version · CE and UK CA marked · Gland M20 · polished tubes 0.76um · 3A & EHEDG certified | Flowmeter E300 ? inch 0-2.000 kg/h | 90531-3438 |
| Same configuration | Flowmeter E300 ? inch 0-6500 kg/h | 90531-3439 |
| Same configuration | Flowmeter E300 1 inch 0-18.000 kg/h | 90531-3440 |
| Same configuration | Flowmeter E300 1? inch 0-45.000 kg/h | 90531-3441 |
| Same configuration | Flowmeter E300 2 inch 0-65.000 kg/h | 90531-3442 |
| Same configuration | Flowmeter E300 3 inch 0-180.000 kg/h | 90531-3443 |
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| DIN 11851 union · 4_20mA + 2x Config. IO · Gland M20 · polished tubes 0.76um · 3A & EHEDG certified | Flowmeter E300 DN08 0-2.000 kg/h | 90531-3444 |
| Same configuration | Flowmeter E300 DN15 0-6500 kg/h | 90531-3445 |
| Same configuration | Flowmeter E300 DN25 0-18.000 kg/h | 90531-3446 |
| Same configuration | Flowmeter E300 DN40 0-45.000 kg/h | 90531-3447 |
| Same configuration | Flowmeter E300 DN50 0-65.000 kg/h | 90531-3448 |
| Same configuration | Flowmeter E300 DN80 0-180.000 kg/h | 90531-3449 |
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| DIN 11864-2A Flange · 4_20mA + 2x Config. IO · Gland M20 · polished tubes 0.76um · 3A & EHEDG certified | Flowmeter E300 DN08 0-2.000 kg/h | 90531-3450 |
| Same configuration | Flowmeter E300 DN15 0-6500 kg/h | 90531-3451 |
| Same configuration | Flowmeter E300 DN25 0-18.000 kg/h | 90531-3452 |
| Same configuration | Flowmeter E300 DN40 0-45.000 kg/h | 90531-3453 |
| Same configuration | Flowmeter E300 DN50 0-65.000 kg/h | 90531-3454 |
| Same configuration | Flowmeter E300 DN80 0-180.000 kg/h | 90531-3455 |
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| SMS union connection · 4_20mA + 2x Config. IO · Gland M20 · polished tubes 0.76um · 3A compliant | Flowmeter E300 SMS25 0-2.000 kg/h | 90531-3456 |
| Same configuration | Flowmeter E300 SMS25 0-6500 kg/h | 90531-3457 |
| Same configuration | Flowmeter E300 SMS25 0-18.000 kg/h | 90531-3458 |
| Same configuration | Flowmeter E300 SMS38 0-45.000 kg/h | 90531-3459 |
| Same configuration | Flowmeter E300 SMS51 0-65.000 kg/h | 90531-3460 |
| Same configuration | Flowmeter E300 SMS76.1 0-180.000 kg/h | 90531-3461 |
Promass F 100 — Clamp
Tri-clamp · polished measuring tubes 0.76um · special density application package
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| Tri-clamp process connection · PROFINET IO · polished measuring tubes 0.76um · ultracompact stainless steel housing | Flowmeter F100 1/2 inch 0-6500kg | 90532-9445 |
| Same configuration | Flowmeter F100 1 inch 0-18000kg | 90532-9446 |
| Same configuration | Flowmeter F100 1-1/2 inch 0-45000kg | 90532-9447 |
| Same configuration | Flowmeter F100 2 inch 0-70000kg | 90532-9448 |
| Same configuration | Flowmeter F100 3 inch 0-180000kg | 90532-9449 |
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| Tri-clamp process connection · Ethernet IP · polished measuring tubes 0.76um · ultracompact stainless steel housing | Flowmeter F100 1/2 inch 0-6500kg | 90532-9450 |
| Same configuration | Flowmeter F100 1 inch 0-18000kg | 90532-9451 |
| Same configuration | Flowmeter F100 1-1/2 inch 0-45000kg | 90532-9452 |
| Same configuration | Flowmeter F100 2 inch 0-70000kg | 90532-9453 |
| Same configuration | Flowmeter F100 3 inch 0-180000kg | 90532-9454 |
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| Tri-clamp process connection · PROFINET IO · EHEDG design · polished tubes 0.76um | Flowmeter F100 1/2 inch 0-6500kg | 90532-9455 |
| Same configuration | Flowmeter F100 1 inch 0-18000kg | 90532-9456 |
| Same configuration | Flowmeter F100 1-1/2 inch 0-45000kg | 90532-9457 |
| Same configuration | Flowmeter F100 2 inch 0-70000kg | 90532-9458 |
| Same configuration | Flowmeter F100 3 inch 0-180000kg | 90532-9459 |
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| Tri-clamp process connection · Ethernet IP · EHEDG design · polished tubes 0.76um | Flowmeter F100 1/2 inch 0-6500kg | 90532-9460 |
| Same configuration | Flowmeter F100 1 inch 0-18000kg | 90532-9461 |
| Same configuration | Flowmeter F100 1-1/2 inch 0-45000kg | 90532-9462 |
| Same configuration | Flowmeter F100 2 inch 0-70000kg | 90532-9463 |
| Same configuration | Flowmeter F100 3 inch 0-180000kg | 90532-9464 |
Promass F 300 — Clamp
Tri-Clamp · EN 1.4404/316/316L · 0.1% accuracy · 4_20 mA HART/Frequency · Touch button display
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| Tri-Clamp · Gland M20 IP68 · Stainless Steel Housing | Promass F300 Tri-Cl.1 inch 0-18000kg | 90529-7966 |
| Same configuration | Promass F300 Tri-Cl.1/2 inch 0-6500kg | 90529-7962 |
| Same configuration | Promass F300 Tri-Cl.3 inch 0-180000kg | 90529-7980 |
Promass Q 300
PROFINET IO · EN 1.4404/316/316L · 0.1% accuracy · IP69K Stainless Steel Housing
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| Tri-Clamp, with display · PROFINET IO | Promass Q300 Tri-Cl.1 inch w display | 90531-0153 |
| Same configuration | Promass Q300 Tri-Cl.2 inch w display | 90531-0154 |
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| Tri-Clamp, without display · PROFINET IO | Promass Q300 Tri-Cl.1 inch | 90529-4522 |
| Same configuration | Promass Q300 Tri-Cl.2 inch | 90529-4521 |
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| SMS union, with display · EN 1.4404/316/316L · Stainless Steel Housing | Promass Q300 SMS25 w display | 90531-0155 |
| Same configuration | Promass Q300 SMS51 w display | 90531-0156 |
| Description | Denomination | Tetra Pak Part Number |
|---|---|---|
| SMS union, without display · EN 1.4404/316/316L · Stainless Steel Housing | Promass Q300 SMS25 | 90531-0157 |
| Same configuration | Promass Q300 SMS51 | 90531-0158 |
How to identify the correct Coriolis flowmeter
Use the full installed configuration rather than selecting only by family name.
Confirm the Promass family
Identify E 100, E 300, F 100, F 300 or Q 300.
Match the connection
Confirm Clamp, DIN union, DIN flange or SMS union together with the exact nominal size.
Match the flow range
Compare the complete denomination and stated kg/h range with the installed instrument.
Verify electronics
Confirm PROFINET IO, Ethernet IP, analog/HART, display and hygienic approval before ordering.
Typical Coriolis process applications
Dairy & beverage
Milk, cream, chocolate, fruit juice, puree and other hygienic liquid applications.
Density & concentration
Direct density measurement, Brix and concentration measurement for process control.
Gas & specialty duties
High-accuracy gas measurement such as CO2 for CSD processes and entrained-gas applications.
Coriolis flowmeter identification
What does a Coriolis flowmeter measure?
The supplied Promass reference highlights direct mass flow and density measurement, with additional concentration and temperature-related capabilities depending on model and configuration.
What is the difference between Promass E, F and Q?
The source positions E for universal standard applications, F for high-accuracy direct mass and density measurement, and Q for premium density and entrained-gas applications.
Can I identify the correct unit only from the pipe size?
No. Connection type, flow range, communication interface, display configuration, approval and exact OEM denomination must also match.
Are Tetra Pak Part Numbers the same as Promass model codes?
No. The OEM denomination/model configuration and the corresponding Tetra Pak Part Number are separate identifiers and are shown independently in the tables.
Does LGN Group manufacture these components?
No. Tetra Pak Part Numbers are presented as OEM references for technical identification and sourcing support.
Why are unclear characters not corrected?
Where the supplied screenshot is not fully legible, the page avoids guessing. Exact OEM identification is more important than filling an uncertain value.
Need help identifying a Promass Coriolis flowmeter?
Send LGN Group the existing Tetra Pak Part Number, Promass model, process connection, nominal size, flow range, communication interface and available nameplate information for technical identification and sourcing support.
Request Technical Support